Back to Home
Green Assistant · Technical Tools

Photosynthetically Active Radiation (PAR) and DLI

Assess light availability for turfgrass in Italy using historical solar radiation data and an explicitly stated conversion to Daily Light Integral.

What is DLI and why does it matter for turfgrass?

Il Daily Light Integral (DLI) represents the total amount of photosynthetically active radiation (PAR) received by a surface over 24 hours. It is expressed in mol/m²/day and quantifies the daily supply of photons available to plants for photosynthesis.

Unlike instantaneous light intensity (PPFD), DLI accounts for the accumulation of light throughout the day.

In turfgrass, light availability affects photosynthesis, carbohydrate production, growth, density, and recovery from stress.

Why measure DLI? Assessing DLI is especially useful on sports pitches and golf greens, where stands, trees, and buildings may substantially reduce available light. Comparing DLI with the requirements of different turfgrass species helps identify potential light limitations and assess management options, including supplemental lighting.

The Green Assistant calculator uses historical solar radiation data to estimate DLI for locations in Italy. Results are estimates of light availability and do not replace direct measurements with PAR sensors.

1. Location and historical data

Search for an Italian municipality, or enter geographic coordinates below.

Select a location and run the calculation.

Source: NASA POWER, ALLSKY_SFC_SW_DWN parameter (daily global solar radiation). DLI is estimated using an indicative conversion factor of 7.38 mol per kWh/m² of global radiation (equivalent to 2.05 mol/MJ). These are not direct PAR measurements. NASA data are spatially averaged and do not account for local shading.

2. Light availability

Mean DLI for the period—mol/m²/day
Lowest monthly DLI—mol/m²/day
Highest monthly DLI—mol/m²/day

Annual light availability

Mean daily DLI by month (mol/m²/day).

The chart will appear after the data load.

3. Turfgrass shading

DLI in full sun—mol/m²/day
Estimated DLI in shade—mol/m²/day
DLI reduction—mol/m²/day

Simplified simulation: the percentage represents an average reduction in daily light integral, not the percentage of shaded hours. Actual shading from stadium structures and trees must be measured or modeled.

4. Stadium shading simulation

Illustrative geometric model of a rectangular pitch surrounded by stands of uniform height. Solar position depends on the city and date. The aerial photograph is an illustrative background: it already shows actual shadows at the time it was taken, whereas the animated shadows are independent estimates and do not reproduce the stadium’s actual geometry.

The selected photograph remains in your browser and is not uploaded to the server.
Illustrative stadium photograph; the pitch rectangle is a schematic overlayReal photograph · Simulated, not measured shadows
Solar elevation—gradi sull'orizzonte
Superficie in ombra—percentuale del campo
Indice DLI diretto residuo (indicativo)—mol/m²/day · campo intero

Residual direct DLI in the nine zones

Enter a city and calculate historical data to obtain a DLI estimate.

The model uses a 105 × 68 m field, simplified continuous stands and a geometric estimate of direct sunlight exposure only. Diffuse light is not quantified, so the result does not represent actual total DLI. Solar geometry is approximate; daily estimates apply the average fraction of unobstructed direct light to the historical monthly mean DLI, not to observed hourly radiation. Roofs, openings, external shadows, reflections and hourly cloud-cover variations are not considered. Do not use these results to size lighting systems without a site survey.

5. Calcolatore manuale PPFD → DLI

DLI calcolato23,04mol/m²/day

Enter only PPFD measured with a PAR sensor, expressed in µmol/m²/s, and exposure hours. Formula: DLI = PPFD × hours × 3600 / 1,000,000. The PPFD value must represent the average over the specified hours; when light intensity varies, measurements must be integrated over time.

6. Documented minimum DLI for the species

Minimum value in the selected study—mol/m²/day

Calculate the location’s DLI first to compare it with the reference value.

The value is an experimental reference obtained from specific plant material, not a universal optimum or a threshold applicable to the entire species. Comparison with a climatic monthly mean is indicative: season, genetic characteristics, mowing height, wear, and temperature affect light requirements. Species without a sufficiently documented threshold do not receive a numerical assessment.

7. Scientific references

Publications by Michael D. Richardson and colleagues (University of Arkansas) on turfgrass light requirements. Findings depend on experimental conditions and do not establish universal species thresholds.

  1. Russell, Karcher e Richardson (2019). Studio sul fabbisogno giornaliero di luce di Agrostis stolonifera su green. Pubblicazione scientifica.
  2. Russell, Karcher e Richardson (2020). Light requirements of warm-season turfgrasses under fairway conditions. Pubblicazione scientifica.
  3. Walton e collaboratori (2025). Effects of shading, mowing height, and plant growth regulators on turfgrass quality. Pubblicazione scientifica.
  4. Richardson e collaboratori (2019). Effetti dell'ombra sui campi sportivi in Cynodon con e senza trasemina di Lolium perenne. Pubblicazione scientifica.
  5. Richardson. Quantifying Shade Environments and Light Requirements for Turfgrasses. Presentazione tecnica (PDF).

Links are provided for bibliographic reference. The threshold shown in the preceding section should be interpreted in relation to intended use and the conditions of the original study.

8. Illuminazione artificiale negli stadi: ricerche e casi applicativi

Studies and technical resources on shading, DLI, and supplemental lighting for sports turf. The entries distinguish experimental studies from practical case reports: results cannot automatically be generalized to every stadium or species.

Illustration of mobile HPS grow lights on a stadium pitch
Collaborazione sperimentale · ICL / Syngenta / STRI

ICL, Syngenta and STRI – Supplemental lighting, nutrition and growth management

Experimental project combining artificial lighting, nutrition and growth regulation. The project presentation is not a peer-reviewed publication reporting conclusive quantitative results.

View original source
Close-up illustration of turfgrass under grow lights
Experimental research · STRI / Syngenta · 2019

Under the spotlight for turf growth

Discussion of the relationship between shade, HPS lighting and Lolium perenne quality. The approximate reference of 10 mol/m²/day relates to the trial conditions and is not a universal threshold.

View original source
Illustration of the pitch shaded by the stands
Caso tecnico · ICL · 2026

Maintaining Grass Cover in a Shaded Stadium – Sheffield Wednesday

Practical experience managing turf cover in a shaded stadium with limited supplemental lighting; this is not a controlled study of lighting efficacy.

View original source
Illustration comparing lampade HPS e LED
Pubblicazione scientifica · 2022

The effects of artificial lighting on sports turf – LED e HPS

Comparative study of supplemental lighting for shaded sports turf: examines quality, density and wear response, distinguishing observed effects from the specific experimental conditions.

View original source
Illustration of red and blue LED lamps for turfgrass
Pubblicazione scientifica · 2026

LED lighting as a solution for turf shading

Research on the effects of LED lighting under shade on Paspalum vaginatum and Zoysia japonica, using physiological and morphological indicators.

View original source
Illustration of experimental plots illuminated with LEDs
University research · University of Tennessee

Supplemental lighting research – LED and HPS

University outreach material discussing LED and HPS lighting research for cool-season and warm-season turfgrasses. This should not be treated as a peer-reviewed experimental article.

View original source

Photo thumbnails are illustrative and come from the stadium photograph already used in the simulator; they are not images taken from the cited articles.